Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 45
Filter
1.
Medicina (Kaunas) ; 60(3)2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38541101

ABSTRACT

Background and Objectives: Unstable atherosclerotic plaque in the arteries is one of the main risk factors for cerebral ischemia. Duplex ultrasound is a frequently used diagnostic method, but it has some limitations for microvascularization and neovascularization evaluation. The aim of this review was to evaluate the role of the new multiparametric US method-contrast-enhanced ultrasound (CEUS)-in atherosclerotic plaque instability verification. Materials and Methods: Original studies, reviews, and meta-analyses were included in this article. A total of 53 studies were retrieved; 29 were included in this study. Results: Carotid artery CEUS as a part of the multiparametric ultrasound method shows promising results and provides additional characteristics of soft- and high-risk atherosclerotic plaques; it can be advised in clinical practice for patients with carotid artery soft- and high-risk plaques. However, there are some limitations, such as extensive calcinosis with important acoustic shadows in carotid atherosclerotic plaque neovascularization diagnostics by CEUS. The added value of CEUS in the characterization of atherosclerotic plaque is that it indicates regions with high neovascularization and visualizes ulcerations on plaque surfaces, suggestive of increased instability risk.


Subject(s)
Carotid Stenosis , Plaque, Atherosclerotic , Humans , Plaque, Atherosclerotic/diagnostic imaging , Carotid Stenosis/diagnostic imaging , Contrast Media , Carotid Arteries/diagnostic imaging , Ultrasonography
2.
Eur Thyroid J ; 13(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38417254

ABSTRACT

Context: Ultrasound-based risk stratification systems (Thyroid Imaging Reporting and Data Systems (TIRADSs)) of thyroid nodules (TNs) have been implemented in clinical practice worldwide based on their high performance. However, it remains unexplored whether different TIRADSs perform uniformly across a range of TNs in routine practice. This issue is highly relevant today, given the ongoing international effort to establish a unified TIRADS (i.e. I-TIRADS), supported by the leading societies specializing in TNs. The study aimed to conduct a direct comparison among ACR-, EU-, and K-TIRADS in the distribution of TNs: (1) across the TIRADS categories, and (2) based on their estimated cancer risk. Methods: A search was conducted on PubMed and Embase until June 2023. Original studies that sequentially assessed TNs using TIRADSs, regardless of FNAC indication, were selected. General study characteristics and data on the distribution of TNs across TIRADSs were extracted. Results: Seven studies, reporting a total of 41,332 TNs, were included in the analysis. The prevalence of ACR-TIRADS 1-2 was significantly higher than that of EU-TIRADS 2 and K-TIRADS 2, with no significant difference observed among intermediate- and high-risk categories of TIRADSs. According to malignancy risk estimation, K-TIRADS often classified TNs as having more severe risk, ACR-TIRADS as having moderate risk, and EU-TIRADS classified TNs as having lower risk. Conclusion: ACR-, EU-, and K-TIRADS assess TNs similarly across their categories, with slight differences in low-risk classifications. Despite this, focusing on cancer risk estimation, the three TIRADSs assess TNs differently. These findings should be considered as a prerequisite for developing the I-TIRADS.


Subject(s)
Thyroid Neoplasms , Thyroid Nodule , Humans , United States/epidemiology , Thyroid Nodule/diagnostic imaging , Thyroid Neoplasms/diagnostic imaging , Data Systems , Retrospective Studies , Tomography, X-Ray Computed , Risk Assessment/methods
3.
EJNMMI Radiopharm Chem ; 8(1): 27, 2023 Oct 12.
Article in English | MEDLINE | ID: mdl-37823964

ABSTRACT

BACKGROUND: In order to support the ongoing research across Europe to facilitate access to novel radionuclides, the PRISMAP consortium (European medical radionuclides programme) was established to offer the broadest catalog of non-conventional radionuclides for medical and translational research. The aim of this article is to introduce readers with current status of novel radionuclides in Europe. MAIN BODY: A consortium questionnaire was disseminated through the PRISMAP consortium and user community, professional associations and preclinical/clinical end users in Europe and the current status of clinical end-users in nuclear medicine were identified. A total of 40 preclinical/clinical users institutions took part in the survey. Clinical end users currently use the following radionuclides in their studies: 177Lu, 68 Ga, 111In, 90Y, other alpha emitters, 225Ac, 64Cu and Terbium isotopes. Radionuclides that would be of interest for users within the next 2-5 years are 64Cu, Terbium radionuclide "family" and alpha emitters, such as 225Ac. CONCLUSIONS: Thanks to a questionnaire distributed by the PRISMAP consortium, the current status and needs of clinical end-users in nuclear medicine were identified.

4.
Case Rep Oncol ; 16(1): 422-430, 2023.
Article in English | MEDLINE | ID: mdl-37384203

ABSTRACT

Up to 3% of all hepatocellular carcinomas (HCCs) present with a tumor thrombus (TT) in the inferior vena cava (IVC) and right atrium (RA). Extensive growth of HCC into the IVC and the RA is associated with a particularly poor prognosis. This clinical condition is related to a high risk of sudden death due to pulmonary embolism or acute heart failure. Therefore, a technically challenging treatment undergoing hepatectomy and cavo-atrial thrombectomy is necessary. We report a 61-year-old man presenting with right subcostal pain, progressive weakness, and periodic shortness of breath for 3 months. He was diagnosed with advanced HCC with a TT extending from the right hepatic vein into the IVC and RA. A multidisciplinary meeting with cardiovascular and hepatobiliary surgeons, oncologists, cardiologists, anesthesiologists, and radiologists was held to determine the best treatment approach. Initially, the patient underwent right hemihepatectomy. As follows, the cardiovascular stage using cardiopulmonary bypass was successfully performed, removing the TT from the RA and ICV. In the early postoperative period, the patient remained stable and was discharged on the 8th postoperative day. A morphological examination revealed grade 2/3 HCC, a clear cell variant with microvascular and macrovascular invasion. Immunohistochemical staining was positive for HEP-1, CD10, whereas negative for S100. The morphological and immunohistochemical results corresponded to HCC. The treatment of such patients requires the cooperation of various specialties. Although the approach of the surgery is extremely complex including specific technical support, as well as high perioperative risks, the result offers favorable clinical outcomes.

5.
Diagnostics (Basel) ; 12(12)2022 Dec 15.
Article in English | MEDLINE | ID: mdl-36553183

ABSTRACT

BACKGROUND: Early diagnosis of recurrent prostate cancer is a cornerstone for further adequate therapy planning. Therefore, clinical practice and research still focuses on diagnostic tools that can detect prostate cancer in early recurrence when it is undetectable in conventional diagnostic imaging. 18F-PSMA-1007 PET/CT is a novel method to evaluate patients with biochemical recurrent PCa. The aim of this review was to evaluate the role of 18F-PSMA-1007 PET/CT in prostate cancer local recurrence, lymph node metastases and bone metastases detection. METHODS: Original studies, reviews and five meta-analyses were included in this article. A total of 70 studies were retrieved, 31 were included in the study. RESULTS: All patients described in the studies underwent 18F-PSMA-1007 PET/CT. The administered 18F-PSMA-1007 individual dose ranged from 159 ± 31 MBq to 363.93 ± 69.40 MBq. Results showed that 18F-PSMA-1007 PET/CT demonstrates a good detection rate in recurrent prostate cancer. CONCLUSIONS: 18F-PSMA-1007 PET/CT appears to achieve reliable performance in detecting recurrent prostate cancer. The high detection rate of 18F-PSMA-1007 PET/CT in recurrent prostate cancer was confirmed, especially in local recurrence and small lymph nodes with non-specific characteristics on conventional diagnostic imaging methods. However, several authors emphasize some limitations for this tracer-for example, non-specific uptake in bone lesions that can mimic bone metastases.

6.
Cancers (Basel) ; 14(14)2022 Jul 10.
Article in English | MEDLINE | ID: mdl-35884418

ABSTRACT

Machine learning (ML) is an interdisciplinary sector in the subset of artificial intelligence (AI) that creates systems to set up logical connections using algorithms, and thus offers predictions for complex data analysis. In the present review, an up-to-date summary of the current state of the art regarding ML and AI implementation for thyroid nodule ultrasound characterization and cancer is provided, highlighting controversies over AI application as well as possible benefits of ML, such as, for example, training purposes. There is evidence that AI increases diagnostic accuracy and significantly limits inter-observer variability by using standardized mathematical algorithms. It could also be of aid in practice settings with limited sub-specialty expertise, offering a second opinion by means of radiomics and computer-assisted diagnosis. The introduction of AI represents a revolutionary event in thyroid nodule evaluation, but key issues for further implementation include integration with radiologist expertise, impact on workflow and efficiency, and performance monitoring.

7.
Case Rep Oncol ; 15(2): 528-534, 2022.
Article in English | MEDLINE | ID: mdl-35813693

ABSTRACT

This report represents an unusually large parathyroid carcinoma (PC) mimicking thyroid nodule recurrence after hemithyroidectomy. PC is a rare endocrine malignancy accounting for less than 1% of hyperparathyroidism cases. This is the first case report where contrast-enhanced ultrasound (CEUS) was performed on a PC. A 63-year-old female presented with an enlarged mass on the left side of the neck. In 2012, left-side hemithyroidectomy was done due to a benign goiter. In 2020, laboratory analysis showed markedly elevated parathyroid hormone and calcium. Multiparametric neck ultrasonography was performed including B-mode, color Doppler, shear wave elastography, and CEUS. Computed tomography revealed an irregular mass in proximity to the trachea, esophagus, and dislocation of the common carotid artery. Perifocal fatty tissue appeared normal. Scintigraphy displayed a suspected parathyroid tumor or a suspected left lobe nodule of thyroid. Based on the biochemical diagnosis of primary hyperparathyroidism and radiological examinations, a suspected parathyroid tumor was considered. Intraoperative findings demonstrated an unusually large 9 × 6 cm tumor (84 g) adjacent to the common carotid artery anterolaterally and the recurrent laryngeal nerve medially. Pathohistological examination revealed a tumor solid in structure, with focal necrosis penetrating the capsule. Immunohistochemical analysis was positive for chromogranin, CD56, and Ki-67 (8-10%) and negative for CK20 and CK7. The morphological and immunohistochemical results correspond to PC. PC is a challenging diagnosis requiring a multidisciplinary approach, especially in the case of previous neck surgery. The only curative treatment for PC is radical surgery. Lifelong monitoring of PCs is mandatory due to the high recurrence rate.

8.
Ultraschall Med ; 43(5): e36-e48, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35850145

ABSTRACT

This first position paper of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) on professional standards presents a common position across the different medical professions within EFSUMB regarding optimal standards for the performing and reporting of ultrasound examinations by any professional ultrasound operator. It describes general aspects of professionality that ensure procedure quality, effectiveness, efficiency, and sustainability in virtually all application fields of medical ultrasound. Recommendations are given related to safety and indication of ultrasound examinations, requirements for examination rooms, structured examination, systematic reporting of results, and management, communication and archiving of ultrasound data. The print version of this article is a short version. The long version is published online.


Subject(s)
Societies, Medical , Humans , Ultrasonography/methods
9.
Ultraschall Med ; 43(5): 456-463, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35850146

ABSTRACT

This first position paper of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) on professional standards presents a common position across the different medical professions within EFSUMB regarding optimal standards for the performing and reporting of ultrasound examinations by any professional ultrasound operator. It describes general aspects of professionality that ensure procedure quality, effectiveness, efficiency, and sustainability in virtually all application fields of medical ultrasound. Recommendations are given related to safety and indication of ultrasound examinations, requirements for examination rooms, structured examination, systematic reporting of results, and management, communication and archiving of ultrasound data. The print version of this article is a short version. The long version is published online.


Subject(s)
Societies, Medical , Humans , Ultrasonography/methods
10.
Medicina (Kaunas) ; 58(2)2022 Feb 09.
Article in English | MEDLINE | ID: mdl-35208581

ABSTRACT

Background and Objectives: The aim of the study was to evaluate the predictive value of the ultrasound criterion "non-marked hypoechogenicity" for malignancy and to determine whether classification of these nodules as TIRADS 3 could improve the overall accuracy of consequently adjusted M-TIRADS score. Materials and Methods: A total of 767 patients with 795 thyroid nodules were subject to ultrasonography examination and ultrasound-guided fine needle aspiration biopsy. Nodules were classified by Kwak TIRADS and modified (M-TIRADS) categories 4A, 4B, and 5 according to number of suspicious US features (marked hypoechogenicity, microlobulated or irregular margins, microcalcifications, taller-than-wide shape, metastatic lymph nodes). Non-marked hypoechoic nodules were classified as TIRADS 3. Results: Thyroid nodules were classified as TIRADS 2, 3, 4A, 4B, and 5 in 14.5, 57.5, 14.2, 8.1, and 5.7%, respectively. Only histopathologic results (125 nodules underwent surgery) and highly specific cytology results (Bethesda II, VI) were accepted as a standard of reference, forming a sub-cohort of 562/795 nodules (70.7%). Malignancy was found in 7.7%. Overall, M-TIRADS showed sensitivity/specificity of 93.02/81.31%, and for PPV/NPV, these were 29.2/99.29%, respectively (OR-18.62). Irregular margins showed the highest sensitivity and specificity (75.68/93.74%, respectively). In TIRADS 3 category, 37.2% nodules were isoechoic, 6.6% hyperechoic, and 52.2% hypoechoic (there was no difference of malignancy risk in hypoechoic nodules between M-TIRADS and Kwak systems-0.9 vs. 0.8, respectively). Accuracy of M-TIRADS classification in this cohort was 78.26% vs. 48.11% for Kwak. Conclusions: The non-marked hypoechoic nodule pattern correlated with low risk of malignancy; classification of these nodules as TIRADS 3 significantly improved the predictive value and overall accuracy of the proposed M-TIRADS scoring with malignancy risk increase in TIRADS 4 categories by 20%; and no significant alteration of malignancy risk in TIRADS 3 could contribute to reducing overdiagnosis, obviating the need for FNA.


Subject(s)
Thyroid Neoplasms , Thyroid Nodule , Humans , Retrospective Studies , Risk Assessment/methods , Thyroid Neoplasms/diagnostic imaging , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology , Ultrasonography/methods
11.
Med Ultrason ; 24(1): 95-106, 2022 Feb 16.
Article in English | MEDLINE | ID: mdl-33945590

ABSTRACT

We recently introduced a series of papers describing how to do certain techniques. This article is the first part of a review of shear wave elastography (SWE). It reports the principles and interpretation of the technique and describes how to optimize it. Normal values, pitfalls and artefacts for the examination of liver, breast. thyroid and salivary gland with shear wave elastography are presented. The manuscript provides specific tips for applying SWE as part of a diagnostic US examination.


Subject(s)
Elasticity Imaging Techniques , Breast/diagnostic imaging , Elasticity Imaging Techniques/methods , Humans , Liver/diagnostic imaging , Reference Values , Thyroid Gland/diagnostic imaging
12.
Med Ultrason ; 24(2): 196-210, 2022 May 25.
Article in English | MEDLINE | ID: mdl-34379714

ABSTRACT

Recently a series of papers was introduced describing on "how to do" certain techniques. More specifically we published on how to perform strain imaging using the transcutaneous and endoscopic ultrasound approach and shear wave elastography (SWE). In the first part we describe how to optimize the examination technique, discussing normal values, pitfalls, artefacts and specific tips for applying SWE to specific organs (liver, breast, thyroid, salivary glands) as part of a diagnostic US examination. In part II, the use of SWE in the pancreas, spleen, kidney, prostate, scrotum, musculoskeletal system, lymph nodes and future developments are discussed.


Subject(s)
Elasticity Imaging Techniques , Breast/diagnostic imaging , Elasticity Imaging Techniques/methods , Humans , Liver/diagnostic imaging , Male , Spleen/diagnostic imaging , Ultrasonography
13.
J Ultrasound Med ; 41(4): 935-949, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34241914

ABSTRACT

OBJECTIVES: This study aimed to define patterns of liver injury after severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection using multiparametric ultrasound (mpUS) in a variable patient population with differing severities of COVID-19. METHODS: Ninety patients were enrolled into the study: 56 had SARS-CoV-2 3-9 months prior to enrolment; 34 served as a clinically healthy control group. All patients underwent an mpUS evaluation of the liver (elastography, dispersion and attenuation imaging). Seventy-six patients had abdominal magnetic resonance (MR) and noncontrast enhanced thoracic computed tomography (CT) scans performed at the same day. All patients were screened for biochemical markers of liver injury. RESULTS: Liver elasticity, viscosity, and steatosis values were significantly altered in patients after COVID-19, with particularly higher fibrosis scores compared to the control group (P < .001). Increased biochemical markers of liver injury correlated with changes in mpUS (P < .05), but not with findings on CT or MR findings. Seventeen of 34 hospitalized patients had a moderate or severe course of the disease course with more pronounced changes in mpUS. Increased body mass index was found to influence liver injury and correlated with more severe forms of COVID-19 (P < .001). CONCLUSIONS: COVID-19 can cause liver injury observable using mpUS. More severe forms of COVID-19 and patient obesity are related to increased values of liver damage observed. In comparison to MRI and CT, mpUS appears to be more sensitive to involvement of liver parenchyma. Further research is warranted to establish this promising method for evaluating post-COVID-19 liver involvement in the aftermath of the pandemic.


Subject(s)
COVID-19 , COVID-19/complications , Humans , Liver/diagnostic imaging , Pandemics , SARS-CoV-2 , Ultrasonography
14.
Cancers (Basel) ; 13(21)2021 Oct 30.
Article in English | MEDLINE | ID: mdl-34771632

ABSTRACT

Ultrasound has been established as a baseline imaging technique for thyroid nodules. The main advantage of adding CEUS is the ability to assess the sequence and intensity of vascular perfusion and hemodynamics in the thyroid nodule, thus providing real-time characterization of nodule features, considered a valuable new approach in the determination of benign vs. malignant nodules. Original studies, reviews and six meta-analyses were included in this article. A total of 624 studies were retrieved, and 107 were included in the study. As recognized for thyroid nodule malignancy risk stratification by US, for acceptable accuracy in malignancy a combination of several CEUS parameters should be applied: hypo-enhancement, heterogeneous, peripheral irregular enhancement in combination with internal enhancement patterns, and slow wash-in and wash-out curve lower than in normal thyroid tissue. In contrast, homogeneous, intense enhancement with smooth rim enhancement and "fast-in and slow-out" are indicative of the benignity of the thyroid nodule. Even though overlapping features require standardization, with further research, CEUS may achieve reliable performance in detecting or excluding thyroid cancer. It can also play an operative role in guiding ablation procedures of benign and malignant thyroid nodules and metastatic lymph nodes, and providing accurate follow-up imaging to assess treatment efficacy.

15.
Cancers (Basel) ; 13(21)2021 Nov 08.
Article in English | MEDLINE | ID: mdl-34771743

ABSTRACT

BACKGROUND: Various Thyroid Imaging and Reporting data systems (TIRADS) are used worldwide for risk stratification of thyroid nodules. Their sensitivity is high, while the specificity is suboptimal. The aim of the study was to compare several TIRADS systems and evaluate the effect of hypoechogenicity as a sign of risk of malignancy on the overall assessment of diagnostic accuracy. METHODS: The prospective study includes 274 patients with 289 thyroid nodules to whom US and risk of malignancy were assessed according to four TIRADS systems-European (EU-TIRADS), Korean (K-TIRADS), TIRADS by American College of Radiology (ACR TIRADS), and modified Kwak et al. TIRADS (L-TIRADS) systems, in which mild hypoechogenicity is not included in malignancy risk suggestive signs. For all thyroid nodules, a fine needle aspiration (FNA) biopsy was performed and evaluated according to the Bethesda system. For all systems, diagnostic accuracy was calculated. RESULTS: Assessing the echogenicity of the thyroid nodules: from 81 of isoechogenic nodules, 2 were malignant (2.1%), from 151 mild hypoechogenic, 18 (12%) were malignant, and from 48 marked hypoechogenic nodules, 16 (33%) were malignant. In 80 thyroid nodules, mild hypoechogenicity was the only sign of malignancy and none appeared malignant. Assessing various TIRADS systems on the same cohort, sensitivity, specificity, PPV, NPV, and accuracy, firstly for EU-TIRADS, they were 97.2%; 39.9%; 18.7%; 99.0%, and 73.3%, respectively; for K-TIRADS they were 97.2%; 46.6%; 20.6%; 99.2%, and 53.9%; for ACR-TIRADS they were 97.2%; 41.1%, 19.0%; 99.0%, and 48.0%, respectively; finally, for L-TIRADS they were 80.6%; 72.7%; 29.6%; 96.3%, and 73.3%. CONCLUSIONS: This comparative research has highlighted that applying different TIRADS systems can alter the number of necessary biopsies by re-categorization of the thyroid nodules. The main pattern that affected differences was inconsistent hypoechogenicity interpretation, giving the accuracy superiority to the systems that raise the malignancy risk with marked hypoechogenicity, at the same time with minor compensation for sensitivity.

16.
Am J Nucl Med Mol Imaging ; 11(5): 395-405, 2021.
Article in English | MEDLINE | ID: mdl-34754610

ABSTRACT

The aim of this study was to compare the diagnostic tools-18F-PSMA-1007 positron emission tomography (PET/CT), magnetic resonance imaging (MRI) and bone scintigraphy for the evaluation of local recurrence, regional lymph nodes and bone metastases of recurrent prostate cancer (PCa). 28 PCa patients after radical prostatectomy and/or radiation therapy and with biochemical relapse were enrolled in this study. The evaluation of local recurrence and regional lymph node metastases was based on results of PET/CT and MRI. Local recurrent disease in 28 patients was detected by PET/CT in 36% (10/28) and by MRI in 32% (9/28) with sensitivity, specificity, accuracy of 90.9%, 100%, 96.4% and 81.8%, 100%, 92.9%, respectively (kappa 0.92, P<0.001). Nodal involvement was confirmed by PET/CT and MRI in 46% (13/28) and 25% (7/28) with sensitivity, specificity and accuracy for PET/CT 92.3%, 93.3%, 92.9% and for MRI-53.8%, 100%, 78.6%, respectively (kappa 0.57, P<0.001). The evaluation of skeletal metastases was based on PET/CT and bone scintigraphy. Bone metastases were seen on PET/CT and bone scintigraphy in 21% (6/28) and 20% (5/25) with sensitivity, specificity and accuracy of 100%; 91.7%; 92.9% and 50.0%; 85.7%; 80.0%, respectively (kappa 0.41, P<0.01). In conclusion, our comparative study demonstrates advantages of 18F-PSMA-1007 PET/CT compared to MRI and scintigraphy for the evaluation of recurrent prostate cancer. Both methods, 18F-PSMA-1007 PET/CT and MRI, detect local recurrence with high accuracy and excellent agreement, which may be attributed to the low urinary background clearance of 18F-PSMA-1007.

17.
BMC Gastroenterol ; 21(1): 370, 2021 Oct 11.
Article in English | MEDLINE | ID: mdl-34635073

ABSTRACT

BACKGROUND: Studies on a new coronavirus disease (COVID-19) show the elevation of liver enzymes and liver fibrosis index (FIB-4) independently on pre-existing liver diseases. It points to increased liver fibrogenesis during acute COVID-19 with possible long-term consequences. This study aimed to assess liver fibrosis in COVID-19 patients by serum hyaluronic acid (HA) and FIB-4. METHODS: The study included the acute COVID-19 group (66 patients, 50% females, mean age 58.3 ± 14.6), the post-COVID group (58 patients in 3-6 months after the recovery, 47% females, mean age 41.2 ± 13.4), and a control group (17 people, 47% females, mean age 42.8 ± 11.0). Ultrasound elastography was performed in the post-COVID and control groups. RESULTS: Sixty-five percent of the acute COVID-19 group had increased FIB-4 (> 1.45), and 38% of patients had FIB-4 ≥ 3.25. After matching by demographics, 52% of acute COVID-19 and 5% of the post-COVID group had FIB-4 > 1.45, and 29% and 2% of patients had FIB-4 ≥ 3.25, respectively. Increased serum HA (≥ 75 ng/ml) was observed in 54% of the acute COVID-19 and 15% of the post-COVID group. In the acute COVID-19 group, HA positively correlated with FIB-4, AST, ALT, LDH, IL-6, and ferritin and negatively with blood oxygen saturation. In the post-COVID group, HA did not correlate with FIB-4, but it was positively associated with higher liver stiffness and ALT. CONCLUSION: More than half of acute COVID-19 patients had increased serum HA and FIB-4 related to liver function tests, inflammatory markers, and blood oxygen saturation. It provides evidence for the induction of liver fibrosis by multiple factors during acute COVID-19. Findings also indicate possible liver fibrosis in about 5% of the post-COVID group.


Subject(s)
COVID-19 , Elasticity Imaging Techniques , Adult , Aged , Aspartate Aminotransferases , Female , Humans , Liver Cirrhosis , Male , Middle Aged , SARS-CoV-2
18.
J Clin Med ; 10(19)2021 Sep 30.
Article in English | MEDLINE | ID: mdl-34640574

ABSTRACT

Ultrasound often represents the first diagnostic step for thyroid nodule evaluation in clinical practice, but baseline US alone is not always effective enough to achieve thyroid nodule characterization. In the last decades new ultrasound techniques, such as CEUS, have been introduced to evaluate thyroid parenchyma as recommended by EFSUMB guidelines, for use in clinical research field, although its role is not yet clear. Several papers show the potential utility of CEUS in the differential diagnosis of benign and malignant thyroid nodules and in the analysis of lymph node involvement in neoplastic pathology. Therefore, we carried out an evaluation of the literature concerning the role of CEUS in three specific areas: the characterization of the thyroid nodule, the evaluation of minimally invasive treatment and loco-regional staging of the lymph node in proven thyroid cancer. According to evidence reported, CEUS can also play an operative role in nodular thyroid pathology as it is able to guide ablation procedures on thyroid nodule and metastatic lymph nodes, to assess the radicality of surgery, to evaluate disease relapse at the level of the margins of ablated regions and to monitor the clinical evolution of necrotic areas in immediate post-treatment setting.

19.
Med Ultrason ; 23(4): 402-409, 2021 Nov 25.
Article in English | MEDLINE | ID: mdl-34113931

ABSTRACT

AIMS: To evaluate the pre-surgical diagnostic value of Multiparametric Ultrasound (MPUS) and Fine Needle Aspiration Cytology (FNAC) in differentiating parotid gland tumors, comparing the results with histology. MATERIALS AND METHODS: The study enrolled 84 patients with parotid gland lesions surgically treated in a single tertiary center and evaluated by MPUS. Each patient underwent FNAC. Histological examination was considered the gold standard. RESULTS: Histology identified 62 benign tumors and 22 malignancies. In the differential diagnosis between malignant and benign lesions, B-mode Ultrasound (US), Color-Doppler US, Contrast-Enhanced US (CEUS), Elastography (USE) and FNAC showed the following values of sensitivity: 82%, 81%, 86%, 77%, 73% respectively; specificity: 97%, 61%, 95%, 71%, 97% respectively; PPV: 90%, 43%, 86%, 50%, 89% respectively; NPV: 93%, 90%, 95%, 88%, 91% respectively; and accuracy: 89%, 71%, 90%, 78%, 84% re-spectively. CONCLUSIONS: CEUS proved to be a valid and accurate method for identifying malignant tumors of parotid gland; the combination of B-mode US with CEUS showed similar diagnostic accuracy, but better sensitivity than CEUS taken alone. USE did not improve the diagnostic performance of the B-mode US, alone or in association with CEUS; however, it revealed the highest diagnostic accuracy in the differentiation between benign lesions. FNAC demonstrated lower values in comparison with CEUS and with USE. Therefore, according to our study, MPUS could be proposed as a valid alternative to FNAC.


Subject(s)
Parotid Gland , Parotid Neoplasms , Biopsy, Fine-Needle , Humans , Parotid Gland/diagnostic imaging , Parotid Neoplasms/diagnostic imaging , Retrospective Studies , Sensitivity and Specificity
20.
Medicina (Kaunas) ; 58(1)2021 Dec 21.
Article in English | MEDLINE | ID: mdl-35056309

ABSTRACT

Background and Objectives: preoperative differentiation of enlarged parathyroid glands may be challenging in conventional B-mode ultrasound. The aim of our study was to analyse qualitative and quantitative characteristics of parathyroid gland lesions, using multiparametric ultrasound protocol-B-mode, Colour Doppler (CD), and contrast-enhanced ultrasound (CEUS)-and to evaluate correlation with morphology in patients with hyperparathyroidism (HPT). Materials and Methods: consecutive 75 patients with 88 parathyroid lesions and biochemically confirmed HPT prior to parathyroidectomy were enrolled in the prospective study. B-mode ultrasound, CD, and CEUS were performed with the subsequent qualitative and quantitative evaluation of acquired data. We used 1 mL or 2 mL of intravenous ultrasound contrast agent during the CEUS examination. Correlation with post-surgical morphology was evaluated. Results: seventy parathyroid adenomas were hypoechoic and well contoured with increased central echogenicity (44.3%), peripheral-central vascularization (47%), and polar feeding vessel (100%). Twelve hyperplasias presented with similar ultrasound appearance and were smaller in volume (p = 0.036). Hyperplasias had a tendency for homogenous, marked intense enhancement vs. peripherally enhanced adenomas with central wash-out in CEUS after quantitative analysis. No significant difference was observed in contrasting dynamics, regardless of contrast media volume use (1 mL vs. 2 mL). We achieved 90.9% sensitivity and 72.7% specificity, 93% positive predictive value (PPV), 87.3% negative predictive value (NPV), and 87.3% accuracy in the differentiation of parathyroid lesions prior to post-processing. In a quantitative lesion analysis, our sensitivity increased up to 98%, specificity 80%, PPV 98%, and NPV 80% with an accuracy of 96.4%. Conclusions: CEUS of parathyroid lesions shows potential in the differentiation of adenoma from hyperplasia, regardless of the amount of contrast media injected. The quantitative analysis improved the sensitivity and specificity of differentiation between parathyroid lesions. Hyperplasia was characterized by homogeneous enhancement, fast uptake, and homogeneous wash-out appearance; adenoma-by peripheral uptake, central wash-out, and reduced hemodynamics. The use of CEUS quantification methods are advised to improve the ultrasound diagnostic role in suspected parathyroid lesions.


Subject(s)
Contrast Media , Parathyroid Glands , Humans , Parathyroid Glands/diagnostic imaging , Parathyroid Glands/surgery , Prospective Studies , Sensitivity and Specificity , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...